Door Information - Flamebreak
| Flamebreak | Valid To | Single Acting Single Doors | Single Acting Double Doors | Double Acting Doors | Quick2Fit | Concealed Closers | Standard Hinge Intumescents | Thermal Transmittance (U) Value (W/m2K) | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| LSASD | ULSASD | LSADD | ULSADD | DASD | DADD | ||||||
| Flamebreak FD30 CF5260 | 23/11/2029 | ✅ | ✅ | ✅ | ✅ | ❌ | ❌ | ✅ | ✅ 1 | 1mm Interdens Below Each Blade In Leaf & Frame |
430 (Plywood Faces) = 1.0 FF630 (MDF Faces) = 1.1 |
| Flamebreak FD60 CF5261 | 13/01/2030 | ✅ | ✅ | ✅ (2) | ✅ (2) | ❌ | ❌ | ✅ | ❌ | 1mm Interdens Below Each Blade In Leaf & Frame |
660 (Plywood Faces) = 0.9 F660 (MDF Faces) = 0.9 |
| (1) Single Acting Door Assemblies Only. FF630, 630 & 430 Blanks Shall Include Full Width Stiles & Rails (No Trimming) (2) Flamebreak 660 Only Minimum Leaf Height = 1200mm - See Door Certificates For Further Information | |||||||||||
| LSASD: Latched Single Acting Single Door | ULSASD: Unlatched Single Acting Single Door | LSADD: Latched Single Acting Double Door | ULSADD: Unlatched Single Acting Double Door | DASD: Double Acting Single Door | DADD: Double Acting Double Door |
| Manufacturer | Max Height (mm) | Max Width (mm) | Max Area (m2) | Multiple Apertures | Min Door Edge Margin (mm) | Min Core Material Between Apertures (mm) |
|---|---|---|---|---|---|---|
| Flamebreak FD30 CF5260 | 1300 (at 700 wide) |
875 (at 1040 high) |
0.91 | ✅ | 100 | 100 | 2063 (at 300 wide) |
375 (at 1650 high) |
0.62 | ✅ | 160 | 160 |
| Flamebreak FD60 CF5261 | 650 (at 600 wide) |
650 (at 600 high) |
0.39 | ✅ | 150 | 150 |
| See Door Certificates For More Information | ||||||