Standard FD30 Intumescent Protection - ARRONE
| Arrone | Doorpac | Flamebreak | Halspan | Premdor | Vicaima | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strebord FD30 | FD30 Blank | Prima FD30 | Optima FD30 | Fireshield | FD30 Moulded Skin | PremCORE | Tubecore Lite | PremCore Lite | FD30 SDC | |||||||||
| Reference | Lock Type | Machining Parameter | Lock Certificate No | CF5228 | CF5260 | CF435 | CF534 | CF195 | CF198 | CF240 | CF380 | CF625 | CF218 | |||||
| AR910R | Sashlock | PAR075 | CF530 | 1mm Interdens Intumescent Sheet Material To Fully Wrap Lock Case & Below Forend & Keep | None Required | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | Forends / Keep Should Be Bedded On Intumescent Mastic OR Both Side Faces Of Lock Case To Be Lined With 1mm Thick Interdens Sheet Material - Minimum Dimensions Of Sheet: 30mm Wide By Full Height Of Lock Case |
NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | ||||||||||
| AR915R | Escape Sashlock | PAR0043 | ||||||||||||||||
| Click Certificate Numbers For Further Information | ||||||||||||||||||