Standard FD60 Intumescent Protection - SALTO
| Salto | Doorpac | Flamebreak | Halspan | Premdor | Vicaima | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strebord FD60 | FD60 Blank | Prima FD60 | Optima FD60 | FD60 PremCORE | FD60 FlaxCore | FD60 Prima | |||||||
| Reference | Lock Type | Machining Parameter | Lock Certificate No | CF5229 | CF5261 | CF436 | CF535 | CF241 | CF302 | CF454 | |||
| LE7S05 | Nightlatch | PAR383 | CF5596 | 2mm Interdens Intumescent Sheet Material To Fully Wrap Lock Case & Below Forend & Keep | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | Salto CF5596 Applies See Notes Below | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | Case, Forend & Keep To Be Bedded Onto 1mm Of Interdens Intumescent Sheet Material | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | ||||
| LE7S15 | Escape Lock | PAR359 | |||||||||||
| LE8P02 | Nightlatch | PAR222 | CF5652 | Salto CF5652 Applies See Notes Below | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | Salto CF5652 Applies See Notes Below | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | Salto CF5652 Applies See Notes Below | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | |||
| LE8P12 | Escape Lock | PAR343 | |||||||||||
| NOTES: All Systems EXCEPT XS4 ONE Ei7xx Electronic Escutcheon: The required protection for 60 minute ITT applications shall be 1mm thick Interdens intumescent sheet material behind the strike plate only. Additionally the perimeter intumescent fire seals within the frame / door edge shall bypass the strike plate / forend by a minimum of 7.5mm wide on each side (with the exception of the latchbolt lip where present) | |||||||||||||
| NOTES: XS4 ONE Ei7xx Electronic Escutcheon: The required protection for 60 minute ITT applications shall be 2mm thick Interdens intumescent sheet material behind the strike plate only. Additionally the perimeter intumescent fire seals within the frame / door edge shall bypass the strike plate / forend by a minimum of 7.5mm wide on each side (with the exception of the latchbolt lip where present) | |||||||||||||
| Click Certificate Numbers For Further Information | |||||||||||||