| Certificate Number | Description | Supplement Number | Issue No | Expiry Date | Notes |
|---|---|---|---|---|---|
| CF5228 | TLJ Systems Identity, Infinity & Invisible Locks - FD30 | Supplement 520520 | 01 | 11/09/2028 | Also Permits The Inclusion of 27mm Maximum Diameter Spindle Holes for Non Tubular Locks & Latches |
| CF5229 | TLJ Systems Identity, Infinity & Invisible Locks - FD60 | Supplement 519034 | 01 | 11/09/2028 | Also Permits The Inclusion of 27mm Maximum Diameter Spindle Holes for Non Tubular Locks & Latches |
| CF5228 | Pocklington Court - 20mm Diameter Spindle Recess for Tubular Latches | Supplement 534889 | 01 | 10/09/2028 | Project Specific to Pocklington Court 2mm Graphite to Circumference of Spindle Recess 1mm Graphite to Fully Wrap Lock Case |
| CF5228 & CF5229 | Mag Locks & Surface Mounted Armature Plates | Supplement 517525 | 01 | 23/05/2028 | Mag Locks to be Wholy Surface Mounted & Shall Not Penetrate Door to Frame Perimeter Gaps |
| CF5228 | NSP 'SMF Epic' Electromechanical Sashlocks, Readers, Keeps, Handles & Escutcheons | Supplement 517525 | 01 | 18/05/2028 | 20 x 4mm Pyroplex (CF355) Perimeter Intumescent Seals Required |
| CF5229 | To Permit the Use of UK Industrial Tapes, Closed Cell Foam Tape Reference 68130 | Supplement 530216 | 01 | 08/05/2028 | Use Sealmaster Closed Cell Foam Tape as Std |
| CF5229 | CE Marked Fire Brigade Locks With max Lock/Case Dimensions: Case: 81mmHigh x 106mm Wide x 16mm Thick Forend: 118mm High x 23mm Wide Keep: 89mm High x 25.5mm Wide |
Supplement 524680 | 01 | 01/12/2027 | 2mm Interdens Fully Wrapping Lock Case & Behind Forend & Keep |
| CF5228 | CE Marked Fire Brigade Locks With max Lock/Case Dimensions: Case: 81mmHigh x 106mm Wide x 16mm Thick Forend: 118mm High x 23mm Wide Keep: 89mm High x 25.5mm Wide |
Supplement 524574 | 01 | 28/11/2027 | 1mm Interdens Fully Wrapping Lock Case & Behind Forend & Keep |
| CF5228 | Addition Of 200mm Flushbolts (See Supplement For Mann McGowan Intumescent Requirements) | Supplement 509450 | 01 | 31/07/2027 | Mann McGowan 500P Perimeter Intumescent Seals Required |
| CF5229 | Addition Of Electric Strikes (Must Include Lock Guard Plates To Both Faces Of Leaf) | Supplement 508206 | 01 | 15/07/2027 | Lock Guards Required to Both Faces of Door Leaf |
| CF5229 | Addition Of 27mm Wide GU Adjustable Strike Plates & 3 Degree Leading Edge | Supplement 516789 | 01 | 15/07/2027 | 3 Degree to be Used in Conjunction With Lorient Type 617 or Pyroplex Graphite Rigid Box Seals Only |
| CF5228 | Addition Of 27mm Wide GU Adjustable Strike Plates | Supplement 515859 | 01 | 08/05/2027 | |
| CF5229 | Addition Of Certifre Approved Concealed Closers To CF5229 FD60 Strebord 54 Door Leaves | Supplement 505791 | 01 | 14/02/2027 | 20mm Hardwood Lip To Leaf Head With 15 x 4mm Intumescent Fitted Centrally |
| CF5228 | Decorative Grooves & Timber Inserts To 54mm FD30 Strebord Blanks | Supplement 506891 | 01 | 09/09/2026 | May Extend to Leaf Edges |
| CF5228 | Addition Of Certifire Approved Dropseals Including Sealed Tight Solutions STS422GT Dropseal | Supplement 506891 | 01 | 09/09/2026 | FD30 Only |
| CF5229 | Certifire Approved Dropseals To FD60 Door Leaves - CF5229 | Supplement 504961 | 01 | 04/08/2026 | Must be Fitted Using Manufacturer's Intumescent Kit |
| CF5228 | Repairs For Incorrectly Fitted Handles - Vinci East Park | Supplement 434543 | 01 | 11/01/2026 | Site Specific Only |
| CAF196 | Retro Fitted Hardwood Timber Lippings To Bottom Edge Of Door Leaves To Reduce Large Threshold Gaps | Supplement 348696 | 02 | 01/08/2025 | Max 20mm Thick Lipping & 30 x 1mm Intumescent to Back Edge |
| CAF196 / CF5228 | Timber System 7 Frames For Use With Doorpac CF5228 Doors | Supplement 370952 | 02 | 14/02/2027 | Increased Thickness Frame Sections |
| CF5229 | Addition Of Timber Panels To Push Face Of Door - Flush Doors & Frames - Timber System 8 | Supplement 358385 | 02 | 20/09/2026 | Rebated Frame Profile Required For Flush Fitted Applications |