Dooorpac CF5228 FD30 Fire Certificate Supplement Register

Certificate Number Description Supplement Number Issue No Expiry Date Notes
CF5228 Floor Fixed Timber Thresholds With Recessed Dropseals Supplement S5013 01 31/07/2030 Hardwood Timber Thresholds min Density 640kg/m3 min 6mm Thick & max 18mm Thick
Option 1: min 44mm Wide & Fitted Between Jambs Directly Below The Door Leaf
Option 2: min Equal To Frame Width & Screw Fixed To The Bottom Of The Jambs Using 2nr ∅4mm x 50mm Screws Per Jamb
CF5228 Vingcard Signature RFID Readers With Euro Lock Option Supplement S5087 01 28/07/2030 Maximum 1100mm From Bottom Of Door To Centreline Of Lock
Euro Lock Case ONLY
ANSI Lock Case NOT Permitted
CF5228 Doors 4mm Proud of the Frame Supplement 523695 01 17/10/2029 15 x 4mm Pyroplex (CF355) Rigid Bix Seals Only
Maximum Leaf Height 2196mm (at 924mm Wide)
Maximum Leaf Width 997mm (at 2040mm High)
Max Area 2.03m2
CF5228 1000mm High x 200mm Wide Steel Push Plates Supplement S5018 01 06/08/2029 Maximum Push Plate Dimensions: 1000mm High x 200mm Wide
Push Plates MUST NOT Occupy More Than 20% of the Door Leaf Area in Total
CF5228 PROJECT SPECIFIC - Barratt London, Ilderton Road
Retro Fitted Repair to Incorrectly Positioned Eye Viewers
Supplement S5016 01 22/07/2029 Site Specific to Barratt London, Ilderton Road Only - NOT For Renewal on Expiry
CF5228 Access Panels With 4 Sided Frames With Upstands Supplement 535111 01 15/07/2029 Maximum Height To Top Of Frame: 2100mm
Maximum Height Of Upstand: 584mm
Maximum Leaf Width: 926mm
Door Leaf & Frame Decrease With Increase In Upstand Height To Maximum Noted Above
CF5228 22mm Diameter Spindle Holes With Tubular Latches - 1mm Interdens to Latches Supplement 535991 01 12/06/2029 Tubular Latches To Be Fully Wrapped In 1mm Thick Interdens
Forend & Keep to be Bedded on 1mm Interdens
CF5228 20mm Diameter Spindle Holes With Tubular Latches - No Additional Intumescent Supplement 536012 01 16/05/2029 No Intumescent Required As Per CF5228
CF5228 Quick2Seal Plus - Intumescent Seal to Back of Frame - FD30 Supplement 523695 01 10/10/2028 40 x 3mm Vanquish FLexifire HE Seal 15mm in From Opening Face in Rear of Frame
CF5228 TLJ Systems Identity, Infinity & Invisible Locks - FD30 Supplement 520520 01 11/09/2028 Also Permits The Inclusion of 27mm Maximum Diameter Spindle Holes for Non Tubular Locks & Latches
CF5228 Pocklington Court - 20mm Diameter Spindle Recess for Tubular Latches Supplement 534889 01 10/09/2028 Project Specific to Pocklington Court
2mm Graphite to Circumference of Spindle Recess
1mm Graphite to Fully Wrap Lock Case
CF5228 &
CF5229
Mag Locks & Surface Mounted Armature Plates Supplement 531312 01 23/05/2028 Mag Locks to be Wholy Surface Mounted & Shall Not
Penetrate Door to Frame Perimeter Gaps
CF5228 NSP 'SMF Epic' Electromechanical Sashlocks, Readers, Keeps, Handles & Escutcheons Supplement 517525 01 18/05/2028 20 x 4mm Pyroplex (CF355) Perimeter Intumescent Seals Required
CF5228 CE Marked Fire Brigade Locks With max Lock/Case Dimensions:
Case: 81mmHigh x 106mm Wide x 16mm Thick
Forend: 118mm High x 23mm Wide
Keep: 89mm High x 25.5mm Wide
Supplement 524574 01 28/11/2027 1mm Interdens Fully Wrapping Lock Case & Behind Forend & Keep
CF5228 Addition Of 200mm Flushbolts (See Supplement For Mann McGowan Intumescent Requirements) Supplement 509450 01 31/07/2027 Mann McGowan 500P Perimeter Intumescent Seals Required
CF5228 Addition Of 27mm Wide GU Adjustable Strike Plates Supplement 515859 01 08/05/2027
CF5228 Decorative Grooves & Timber Inserts To 54mm FD30 Strebord Blanks Supplement 506891 01 09/09/2026 May Extend to Leaf Edges
CF5228 Addition Of Certifire Approved Dropseals Including Sealed Tight Solutions STS422GT Dropseal Supplement 506891 01 09/09/2026 FD30 Only
CF5228 Repairs For Incorrectly Fitted Handles - Vinci East Park Supplement 434543 01 11/01/2026 Site Specific to Vinci East Park Only
CAF196 / CF5228 Timber System 7 Frames For Use With Doorpac CF5228 Doors Supplement 370952 02 14/02/2027 Increased Thickness Frame Sections